ID5000 Series Smart Code Reader User Manual
60
Select Soft Trigger Active
If you select
Soft Trigger Active
as
Line Out Activation Event
, you can set its output delay time,
duration, and execute outputting signal manually.
Line Out Delay Time
It sets the delay time for outputting the output signal.
Line Out Duration
It sets the time duration of the output signal.
Line Trigger Software
Click
Execute
for manually outputting the output signal.
Figure 8-46 Select Soft Trigger Active
Select Hard Trigger Active
If you select
Hard Trigger Active
as
Line Out Activation Event
, you can set its output delay time,
duration, trigger source, and trigger activation.
Line Out Delay Time
It sets the delay time for outputting the output signal.
Line Out Duration
It sets the time duration of the output signal.
Hardware Trigger Source
It sets the hardware trigger source, including
LineIn 0
,
LineIn 1
, and
LineIn 2
.
Hardware Trigger Activation
It sets the trigger activation of input signal, including
Rising Edge
and
Falling Edge
.
Summary of Contents for ID5000 Series