Electrical
Power
Model
Maximum Rated Power
Studio Command 1200
230 V @ 6.1 AMP
1400 W
Studio Command 700
230 V @4.3 AMP
1200 W
Studio Command H
230 V @ 5.2 AMP*
1200 W
* Total fixture and dimmer controlled lamp
Fuses
Logic Board Fuses:
F1 - 2.5 A, 250 V, Slow Blow only (5 mm x 20 mm)
F2 - 2.5 A, 250 V, Slow Blow only (5 mm x 20 mm)
Motor Power Supply Fuses:
F1 - 6.3 A, 250 V, Slow Blow only (5 mm x 20 mm)
F2 - 6.3 A, 250 V, Fast Blow only (5 mm x 20 mm)
Filter Board Fuses:
F1 - 16 A, 250 V, Fast Blow only (5 mm x 20 mm)
F2 - 16 A, 250 V, Fast Blow only (5 mm x 20 mm)
Voltage Surge: A surge of 2000 V or more may damage the power supply.
WARNINGS:
Minimum distance to flammable objects: 3.28 ft (1.0 m)
Minimum distance to lighted object: 6.56 ft (2.0 m)
Do not mount on a flammable surface.
Warning: Class 1 equipment - This equipment must be earthed.