Page 42 of 83
October 2013
© 2013 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
DTC4500e Card Printer User Guide, PLT-01669, 1.0
Setting
Option
Ribbon Blue LED Level
This is a calibration driven value and should not be adjusted.
Note:
This is factory set and should not be changed unless
directed by a technician.
Ribbon Print Tension
Use the Ribbon Tension option to increase or decreases the
amount of tension (drag) on the Ribbon during printing.
Flipper Home Offset
This is a calibration driven value and should not be adjusted. If the
flipper unit is replaced and has not been calibrated this value may
need to be adjusted.
Note:
This is factory set and should not be changed unless
directed by a technician.
Flipper Lam Height Offset
This is a calibration driven value and should not be adjusted. If the
flipper unit is replaced and has not been calibrated this value may
need to be adjusted.
Note:
This is factory set and should not be changed unless
directed by a technician.
Mag HI-Co Voltage Offset
This option changes the voltage going to the magnetic head.
Note:
This is factory set and should not be changed unless
directed by a technician.
Mag Lo-Co Voltage Offset
This option changes the voltage going the magnetic head.
Note:
This is factory set and should not be changed unless
directed by a technician.
OLED Contrast
(display contrast)
Use this option to increase or decrease the contrast of the printer
OLED (if applicable.
Resin Heat Adjust
Use this adjustment for Black resin text and barcodes if they
appear faded or too light/dark.
•
Maximum Adjustment Range is +/- 100.
Note
: This control can be helpful for fine-tuning the transfer of resin
text and bar codes.
Head Resistance
This is factory set. If the main board or the printhead is replaced
then adjust this number.
Locate the Printhead Setting Number on the bottom of the
printhead.
The number reads R=XXXX.
Head Home Offset
This is a calibration driven value and should not be adjusted. If the
printhead assembly is replaced then this value may need to be
adjusted.
Note:
This is factory set and should not be changed unless
directed by a technician.
Head Contact Offset
This is a calibration driven value and should not be adjusted. If the
Printhead assembly is replaced then this value may need to be
adjusted.
Note:
This is factory set and should not be changed unless
directed by a technician.
Summary of Contents for FARGO DTC4500e