Introduction
Improper use
■
The combination of natural and forced circulated air results in low
drying-out rates of the cultures, high temperature consistency and
precise temperature distribution. Therefore, the incubator is suit-
able for incubating human pathogens, which
–
require a characteristic optimum temperature (campylobacter
jejuni or coli at 42°C, e.g.: of clostridium difficile at 36°C).
–
require long-term cultures (mycobacterium tuberculosis at
36°C / up to 8 weeks).
■
Also the incubation tasks of similar materials and samples with
equally high demands are possible.
■
The incubator is only intended for this purpose.
■
Another use or one which goes beyond this, is considered to be
non-intended. The company Andreas Hettich GmbH & Co. KG is
not liable for damage resulting from this.
■
Observing all information in the operating instructions and com-
plying with the measures described therein is also a part of the
intended use.
Another use or a use going beyond the intended use is considered to
be improper. The company Andreas Hettich GmbH & Co. KG is not
liable for damage resulting from this.
■
Operation in a potentially explosive, biologically, chemically or
radioactively contaminated atmosphere.
■
It is forbidden to put flammable or explosive materials or materials
which chemically react together with high energy in the incubator.
■
The presence of persons or animals inside the incubator.
■
Using the incubator or its accessories as a climbing aid.
■
Operation outdoors.
■
Use on moving subsurfaces, e.g. ships, rail transport or airplanes.
■
Stacks of impermissible incubator sizes and stacks without fixa-
tion (allowed is a stack of a total of two incubators of size
200/200 R.).
■
The incubator in the standard configuration is not intended to be
used in continuous cooling operation.
1.6
Replacement parts/consumable material
Only original spare parts and original accessories approved by the
manufacturer may be used.
WARNING
If no original spare parts or original accessories are
used, the warranty as well as liability claims against
the company Andreas Hettich GmbH & Co. KG are
void.
1.7
Scope of delivery
■
1 x incubator
■
1 x mains cable (power supply)
■
1 x operating instructions
Summary of Contents for HettCube 200
Page 151: ...151 174 en 12 2020 Rev 02 AB66005 Index W Warning symbols 7 Warnings and error messages 126 ...
Page 152: ...en 12 2020 Rev 02 AB66005 152 174 Index ...
Page 153: ...13 Appendix ...
Page 154: ......
Page 166: ...en 12 2020 Rev 02 AB66005 166 174 Examples ...
Page 170: ...en 12 2020 Rev 02 AB66005 170 174 Accessory overview ...
Page 171: ...171 174 en 12 2020 Rev 02 AB66005 Declaration of conformity D Declaration of conformity ...