9
Menu navigation and adjustment values
34
Term
Description
Unit
In-/Outputs
1 2 3 4
5
6 7 8
Fault central de-ashing
system
Display input error central ash discharge.
If the indicator lamp lights up a fault is active.
-
Release central de-ashing
system
Indicates the state of the release of the central de-ashing system:
If switch on green
->
Output active.
-
Heat exchanger cleaning
(HEC)
Displays the condition of the HEC:
If switch on green
->
Output active.
-
Motor protection Heat
exchanger cleaning
Indicate the status of the motor protection HEC:
If the indicator lamp lights up, the motor protection HEC input has
released.
-
Bypass flap close
Indicates the status of the Bypass flap output
If switch on green
->
Output active
-
In-/Outputs
1 2 3 4 5
6
7 8
Release FC ID-FAN
Indicates the state of the FC ID-fan:
If switch on green
->
Output active
-
Fault FC ID-FAN
Indicates the state of the FC ID-fan:
If the indicator lamp lights up, the fault FC ID-FAN input has released.
-
ID fan
Display the status of the ID-fan:
% / Pa
Primair ½
Display the status of the prim air:
%
Secondary air ½
Display of the current status of the secondary air
%
In-/Outputs
1 2 3 4 5 6
7
8
Ignition heating
Indicates the status of the ignition heating:
If switch on green
->
Output active.
-
Ignition fan
Indicates the status of the ignition fan:
If switch on green
->
Output active.
-
STL
Indicates the input of the safety temperature limiter (STL): If the indicator
lamp lights up, the STL has tripped.
Float switch
Indicates the status of the Float switch:
- If the indicator lamp lights up, the Float switch is activated and a warning
will be displayed
-
Safety pressure limiter
SDB
Indicates the status of the Safety pressure limiter SDB
- If the indicator lamp lights up, the SDB is activated and a warning will be
displayed
-
Additional input
Indicates the state of the additional input.
▪
If the indicator lamp lights up, the additional input is active (there is an
error)
At the additional input, the message of an external unit (CO detector,
extinguishing water tank, system pressure monitoring, etc.) can be
detected, for example.
-
In-/Outputs
1 2 3 4 5 6 7
8
Output temperature
monitoring control (TÜB)
Displays the state of the Output temperature monitoring control:
If switch on green
->
Output active.
-
Temp. monitoring control
storage room
Displays the state of the Output temperature monitoring control storage
room:
If the indicator lamp lights up, the maximum storage room temperature is
exceeded (the storage room temperature control sensor is active).
-
Sum annoyance
Displays the condition of the Sum annoyance:
If switch on green
->
Output active (active fault).
-
Operating alarm unit
Displays the condition of the Operating alarm unit:
If switch on green
->
Output active.
-
Summary of Contents for BioFire 1000
Page 1: ...OPERATING INSTRUCTIONS Wood chips pellets heating system BioFire 500 600 800 1000 1250 1500 ...
Page 89: ...Annex 14 89 14 ANNEX 14 1 Additional boiler module Hydraulic recommendation 1 ...
Page 90: ...14 Annex 90 Hydraulic recommendation 2 ...
Page 91: ...Annex 14 91 14 2 Solar module Program 1 ...
Page 92: ...14 Annex 92 Program 2 ...
Page 93: ...Annex 14 93 Program 3 ...
Page 94: ...14 Annex 94 Program 4 ...
Page 95: ...Annex 14 95 Program 5 ...
Page 96: ...14 Annex 96 Program 6 ...
Page 97: ...Notes 15 97 15 NOTES ...