Replacing a defective flash tube
DANGER
In the case of a defective flash tube, the electrodes are
exposed. Touching the flash tube may result in an electric
shock.
Switch off the device.
Disconnect the device from the power supply or remove
the rechargeable battery.
Before touching the defective flash tube, wait for 15
minutes to allow the capacitor voltage in the device to
drop.
If the flash tube is broken, do not touch the electrodes
under any circumstance. Always use pliers with
protective insulation to remove the flash tube.
To replace the flash tube, proceed as follows:
Switch off the device at the main switch.
Wait for 15 minutes.
Remove the light shaping tool (see page 31).
Remove the protection glass (see page 29).
Unwind the trigger wire (2) from the connection pin (1).