![Henny Penny Evolution Elite EEE-153 Operator'S Manual Download Page 75](http://html1.mh-extra.com/html/henny-penny/evolution-elite-eee-153/evolution-elite-eee-153_operators-manual_2124327075.webp)
71
Problem
Cause
Correction
POWER switch ON but
fryer completely
inoperative
• Open circuit
• Plug fryer in
• Check breaker or fuse at supply box
• (Non-US/some Int’l. locations
only)
Breakers in fryer tripped-open
left door and reset breaker on fryer;
See below
Oil will not heat but lights
are on
• All power cords not
not plugged-in
• Unit has 2 power cords; make sure
both are plugged-in
Control error code “E-10” • Open high limit circuit • Let unit cool down (15-20
minutes), reset the high limit using
the high limit tool on the inside of
the LH door and gently pushing it
into the hole in the heating element
hinge; if high limit does not reset,
high limit must be replaced
Vat is under-filled
• BIB is low or empty
• BIB oil line is clogged
or collapsed
• Filter pan needs
cleaned
• Fill the BIB
• Check BIB line
•
Clean filter pan and change paper
or pad
7-1. TROUBLE SHOOTING GUIDE
SECTION 7. TROUBLESHOOTING
Aug. 2011