8.
After trying to fill the vat 3 times without success, the controls then
shows “CHANGE FILTER PAD?” “YES NO”. If changing the filter
pad at this time, press √
and change filter pad following the proce
-
dures in the Changing
the Filter Pad or Paper Section. Controls
return to normal operation.
If filter pad is to be changed at a later time, press X button and
“CHANGE FILTER PAD?” reminder shows 15 minutes later.
9.
During the next AIF with a new filter pad, if the vat is not filled after
3 tries, the display shows “FILTER SERVICE REQUIRED-SEE
TROUBLESHOOTING GUIDE”.
10.
If the “Service Required” message appears, then every 15 minutes the
display shows “FILTER PROBLEM FIXED? YES NO”. If the prob-
lem has not been fixed, press X button. Once the problem has been
resolved, press
√
and controls return to normal operation.
To help ensure the vat fills completely, make sure filter pan is cleaned at
least daily, filter pad is changed, make sure JIB is full and that “O” rings
on the filter pan are in good condition.
3-10.
B FILTER - SMART TOUCH
(continued)