HelmPak Press Control
36
Users Guide
CHANNEL (1, 2, 3, 4) LOW TREND
This fault occurs when all of the following events occur:
•
When the current peak load has met or become below the low tolerance percentage
or tonnage setting from the sample tonnage.
Clearing fault:
1. Verify die height
2. Press the fault reset push button
CLUTCH/BRAKE MODE CHANGE
This fault occurs when all of the following events occur:
•
When the clutch is engaged and the mode selector switch is changed
Clearing fault:
1. Inch the press to top if needed
2. Press the fault reset push button
CLUTCH COOLANT FAULT
This fault occurs when all of the following events occur:
•
The Grease Motor is ON
•
There is no input to I:6/0 on processor B
•
A thirty second timer has be satisfied
Clearing fault:
1. Verify they Coolant Fault Input, B I:6/0
2. Press the fault reset push button
CLUTCH VALVE FAULTED
This fault occurs when all of the following events occur:
•
When there is no input to I:4/12 on processor B
Clearing fault:
1. Press the fault reset push button; this will energize the reset solenoid.
CLUTCH VALVE FAILED TO TURN OFF
This fault occurs when all of the following events occur:
•
When either processor is not outputting the valve signal but the other processor is
outputting
•
A two second timer has been satisfied
Clearing fault:
1. Press the fault reset push button
CLUTCH VALVE FAILED TO TURN ON
This fault occurs when all of the following events occur:
•
When either processor is outputting the valve signal but the other processor is not
•
A two second timer has been satisfied
Clearing fault:
1. Press the fault reset push button