HelmPak Press Control
42
Users Guide
SLIDE ADJUST IN ON POSITION
This fault occurs when all of the following events occur:
•
The slide adjust key switch is in the on position
Clearing fault:
1. Turn the slide adjust key switch OFF
2. Press the fault reset push button
SLIDE ADJUST UP LIMIT
This fault occurs when all of the following events occur:
•
The slide adjust upper limit is not made, signal A I:2/7 should be high.
Clearing fault:
1. Move slide down, until switch is made and signal is high.
2. Verify switch is working
3. Press the fault reset push button
TANK LUBE LOW LEVEL
This fault occurs when all of the following events occur:
•
The level switch input is not present (B I:6/3)
•
A three second timer was satisfied
Clearing fault:
1. Verify Tank Lube Level, add if needed.
2. Verify Level switch input (B I:6/3)
3. Press the fault reset push button
TONNAGE CHANNELS SCALE FACTOR EQUALS “0”
This fault occurs when all of the following events occur:
•
When the SCALE FACTOR is equal to 0
Clearing fault:
1. Adjust the SCALE FACTOR
2. Press the fault reset push button
TONNAGE LOOK WINDOW FAULT
This fault occurs when all of the following events occur:
•
When either the ON or OFF angle is equal to 0
•
When the ON and OFF angles are equal
•
When the OFF angle is less than the ON angle
Clearing fault:
1. Adjust the ON or OFF angles.
2. Press the fault reset push button
UNCOMMANDED MOTION
This fault occurs when all of the following events occur:
•
When the cross check between processors does not match up
Clearing fault:
1. Verify each processors indicated position on the setup screen
2. Press the fault reset push button