HelmPak Press Control
21
Users Guide
Tonnage
Calibrate
This screen should only be accessed by Service Technicians when the press needs to be calibrated.
The 4 channels of Tonnage are all displayed individually
The Setup/Peak Push Button Determines the mode of the Tonnage Module
The Look window Start / Stop Values are the angles in which the system samples the tonnage inputs
The Low Alarm Inhibit Count displays the number of consecutive machine cycles where low alarm is
inhibited. Used in a process where machine cycles several times before running speed is established.
The Samples button displays the number of machine cycles to establish a sample value (default 16)
The Scale Button displays the value used to describe the press/machine overall tonnage. Set for
maximum value of one channel. For example, settings for a 150 ton two channel press = 75.
From this window you can return to the Main System Setup screen or the Main Tonnage screen.