HelmPak Press Control
38
Users Guide
GREASE LOW LEVEL
This fault occurs when all of the following events occur:
•
The low level input B I:6/4 is present
•
A three second timer was satisfied
Clearing fault:
1. Verify the grease level, add if needed.
2. Press the fault reset push button
GREASE MOTOR CONTACTOR FAULT
This fault occurs when all of the following events occur:
•
The contactor output and aux contact input did not match
Clearing fault:
1. Function check the contactor
2. Press the fault reset push button
HYDRAULIC OVERLOAD
This fault occurs when all of the following events occur:
•
The overload limit switch input is not present (B I:6/8)
•
The press is between 270 to 90 and the selector switch is set to test
Clearing fault:
1. Verify the switch position and the limit input
2. Press the fault reset push button
LUBE SENSOR 1-7 (warning only)
This fault occurs when all of the following events occur:
•
The lube sensor is not ON for longer than 40 seconds
Clearing fault:
1. Verify the lube is flowing and the sensor is operating
2. Press the fault reset push button
MAIN MOTOR DRIVE FAULT
This fault occurs when all of the following events occur:
•
The Drive Fault signal is not present on Processor B I:4/5
Clearing fault:
1. Press the fault reset push button
MAIN MOTOR NOT RUNNING FORWARD
This fault occurs when all of the following events occur:
•
The Key Switch is in the Single or Auto Stroke position
•
The Motor is not running forward
Clearing fault:
1. Place Key Switch in the Inch Position
2. Start the Main Motor
3. Press the fault reset push button