Programming and Operation
3-56
P/N 8040406
C
HELIX TECHNOLOGY CORPORATION
-
TI
CRYOGENICS
Select Relay 1 or 2
The first parameter of the RELAYS function allows you to select setpoint
relay 1 or 2 to be programmed as shown in Figure 3-48.
Figure 3-48: Select Relay 1 or 2 Display
Table 3-4: RELAYS Function Parameters
RELAYS Parameter
Range of Values
Relay 1 or 2
1 - 2
Relay ON/OFF, Auto/Manual
ON/OFF Auto/Manual
First Stage Temperature
30K - 310K
Second Stage Temperature
10K - 310K
Cryo TC Pressure
1 - 999 microns
Aux TC Pressure
1 - 999 microns
Cryopump
ON/OFF
REGEN Track
ON/OFF
Rough Valve
ON/OFF
Time Delay
0 - 99 seconds
Last
Next
Clear
MONITOR
REGEN
SERVICE
CONTROL
RELAYS
HELP
oo
ON
-BOARD
®
Enter
1
2
3
4
5
6
7
8
9
-
0
.
RELAY 1 OR 2?