Programming and Operation
3-22
P/N 8040406
C
HELIX TECHNOLOGY CORPORATION
-
TI
CRYOGENICS
Extended Purge
1. Press the REGEN key on the keypad/display. The current
REGEN status is displayed.
2. Press the Next key until the extended purge value is displayed in
minutes.
3. Press the Enter key. The current value is underlined and ready to
accept a new value.
4. Press the numeral keys for the desired extended purge time. For
example: 1, 5, and 0 for 15.0. The range of values is 0 - 9999
minutes.
NOTE: The Clear key may be pressed if incorrect data has been entered.
The On-Board software allows you to enter the new value.
5. Press the Enter key. Extended purge programming is complete.
6. Press the MONITOR key. The On-Board microprocessor will
monitor system operation.
Repurge
1. Press the REGEN key on the keypad/display. The current
REGEN status is displayed.
2. Press the Next key until the repurge value is displayed in minutes.
3. Press the Enter key. The current value is underlined and ready to
accept a new value.
4. Press the numeral keys for the desired repurge time. For example:
1, 5, and 0 for 15.0. The range of values is 0 - 9999 minutes.
NOTE: The Clear key may be pressed if incorrect data has been entered.
The On-Board software allows you to enter the new value.
5. Press the Enter key. Repurge programming is complete.
6. Press the MONITOR key. The On-Board microprocessor will
monitor system operation.
Repurge Cycles
1. Press the REGEN key on the keypad/display. The current
REGEN status is displayed.
2. Press the Next key until the current number of repurge cycles is
displayed.