On-Board FastRegen Control Module Programming and Operation Instructions
P/N 8040406
3-21
C
HELIX TECHNOLOGY CORPORATION
-
TI
CRYOGENICS
Delay Restart
1. Press the REGEN key on the keypad/display. The current
REGEN status is displayed.
2. Press the Next key until the current delay restart time value is
displayed in hours.
3. Press the Enter key. The current value is underlined and ready to
accept a new value.
4. Press the numeral keys for the desired delay time. For example: 1,
5 for 1.5, or 1, 5, and 0 for 15.0. The range of values is 0 - 999.9
hours.
NOTE: The Clear key may be pressed if incorrect data has been entered.
The On-Board software allows you to enter the new value.
5. Press the Enter key. Delay restart programming is complete.
6. Press the MONITOR key. The On-Board microprocessor will
monitor system operation.
Fast Rough Test
1. Press the REGEN key on the keypad/display. The current
REGEN status is displayed.
2. Press the Next key until the current fast rough test value is
displayed in seconds.
3. Press the Enter key. The current value is underlined and ready to
accept a new value.
4. Press the numeral keys for the desired fast rough test time. For
example: 1, 5, and 0 for 15.0. The range of values is 10 - 999
seconds.
NOTE: The Clear key may be pressed if incorrect data has been entered.
The On-Board software allows you to enter the new value.
5. Press the Enter key. Fast rough test programming is complete.
6. Press the MONITOR key. The On-Board microprocessor will
monitor system operation.