3 Parameterization of HEINZMANN Speed Governors
14
Programmer PG 02
DcDesk 2000 in an identical form and offers easy access to any of the base points.
Furthermore, the characteristics and maps can be represented graphically by this tool.
3.8
Reset of Control Unit
A reset is tantamount to powering down the control and restarting it. This can be achieved
by shortly turning off the power supply.
A reset will clear any data that has not been saved in the control's permanent memory. It is,
therefore, imperative that before executing a reset all data be transferred to the control's
permanent memory if this data is to be preserved.
Certain functions of the Digital Control can be activated only following a reset. These are
mostly functions that serve the purpose to put the control into some other operating state,
or parameters that for safety reasons cannot be modified during operation. The parameters
and functions belonging to this category will be explained in detail in the respective
chapters.
A reset has to be executed only with the engine stopped.
Warning