15
Rev. 05/2020
CHAPTER 6
WARNINGS AND PRECAUTIONS
Please read the following list of cautions, warnings and dangers before installing
and operating your HEATMOR™ STAINLESS STEEL OUTDOOR FURNACE. If you
have any questions or concerns regarding any of the following cautions, warnings,
dangers or instructions in this Operations and Maintenance manual, please contact
your local dealer.
Installation
Installation should be performed by a qualified installer and will comply with all the
requirements of the authority having jurisdiction over the installation.
1) The HEATMOR™ furnace is designed for outside installations, away from
other buildings.
2) Please observe the following “ Clearance to Combustibles “ guidelines.
To unit back = 96 inches
To unit sides = 6 inches
To unit front = 48 inches
To chimney = 96 inches
To unit top = 18 inches
3) Before installing the furnace, always check any and all applicable provincial
and local regulations.
4) A HEATMOR™ Stainless Steel Outdoor Furnace should be located with
consideration to your neighbor’s property and in accordance with local
ordinances. HEATMOR™ Outdoor Furnaces, Model 100
CSS, 200 CSS and
Model 400
CSS, are not designed to be located in densely populated areas.
5) HEATMOR™ suggests the use of brass fittings when installing the unit.
6) Before installing the HEATMOR™ furnace, contact and inform your
insurance agent.
7) The HEATMOR™ Outdoor Furnace is to be installed on a concrete base only.
Any attempt to place the furnace on any other surface may void the warranty.
8) Do not connect the HEATMOR™ furnace to the chimney of any existing
heating system.
9) This unit was not designed, nor is it recommended, for use as a stand-alone
heating system. A back up source of heat must be in place to prevent the outdoor
furnace from freezing and to provide supplementary heat for the heated
buildings.
10) Do not pressurize the HEATMOR™ Outdoor Furnace. This unit is designed to
operate under atmospheric pressure only.
11) Place the in-line fill/drain assembly in a location where the drained contents
of the HEATMOR™ will not cause damage to the surrounding areas or it’s contents.