66
Rev. 05/2020
CHAPTER 22
DOMESTIC COIL (OPTIONAL)
Principle of the Domestic Coil
The domestic coil provides a method of heating HTF indirectly through water-to-water
convection. This method of heating needs to be planned from the initial stages of
purchasing your HEATMOR™. A HEATMOR™ Outdoor Furnace must be special ordered
and manufactured with a special hole at the back of the furnace to accommodate the
domestic coil.
Operation of the Domestic Coil
The coil is inserted at the rear of the furnace through a hole in the water jacket and
fastened by nuts and bolts. The domestic coil plate is sealed to the outer face of the water
jacket by a sealing gasket. As HTF passes through the domestic coil, the HTF in the water
jacket heats it.
Maintenance / Result
1) Make sure a tight seal is maintained between the coil plate and the outer face of the
water jacket.
2) Firmly fastened connections are essential to ensure there are no leaks.
Removal and Replacement
If you suspect you have a leak or faulty internal coil requiring replacement, contact your
local dealer.