Heatilator • ECLIPSE-32, ECLIPSE-36 Installation Manual • 2297-984 Rev. B • 6/15
B. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances as speci
fi
ed. Framing closer than the minimums listed
must be constructed entirely of non-combustible materials
(i.e., steel studs, concrete board, etc.).
Figure 10.3 Clearances To Combustibles Mantels Or Other
Combustibles Above Appliance
Note:
All
measurements
in inches.
Figure 10.4 Non-Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Figure 10.5 Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
5 6
7
8 9
10
3
4
5
12
11
10
9
8
7
6
TOP OF HOOD OR FIREPLACE OPENING
4
12
13
11
32
CEILING
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
See Dimension V on Appliance
Dimension Diagram (Figure 3.1).
3 FT. MAXIMUM
TOP VIEW
2-7/8 IN.
MINIMUM
1/2 IN.
MINIMUM
Note:
Clearance from
opening to perpendicular wall.
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
5-3/8 IN.
MINIMUM
3 IN.
MINIMUM
Note:
Clearance from
opening to perpendicular wall.
UNLIMITED
MANTEL LEG OR WALL PROJECTIONS
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
Figure 10.6 Non-Combustible Zone
1/2 in. SHEETROCK
OR COMBUSTIBLE
MATERIAL
3-1/2 in.
1/2 in.
NON-COMBUSTIBLE ZONE
Note:
Measurement is taken from top of the
opening, NOT the top of the
fi
replace.