16
Heatilator • ECLIPSE-32, ECLIPSE-36 Installation Manual • 2297-984 Rev. B • 6/15
V
1
Minimum**
H
1
Maximum
90 Elbow Only**
2 ft.
610 mm
1/2 ft.**
152 mm
2 ft.
610 mm
1-1/2 ft.** 457 mm
3 ft.
914 mm
2-1/2 ft.** 762 mm
5 ft.
1.5 m
3-1/2 ft.
1.1 m
7 ft.
2.1 m
4-1/2 ft.
1.4 m
15 ft.
4.6 m
H
1
MAX. =15 ft. (4.6 m)
V
1
+ H
1
MAX. = 40 ft. (12.2 m)
** See Warning.
Figure 4.8
Top Vent - Horizontal Termination
One Elbow
Note
: There MUST be a 25% reduction
in total H when using
fl
ex vent except
when using the simple up and out
installation (see Figure 4.6).
Fire Risk.
• When using SLP-HRC-SS and SLP-HRC-ZC-SS
termination caps on top vented
fi
replaces, a one
foot minimum vertical vent section is required
before installing
fi
rst elbow.
• When using DVP-TB1 termination cap on top
vented
fi
replaces, a three foot minimum vertical
vent section is required before installing first
elbow.
WARNING**
Note: Use SLP Series
components only.
H
1
V
1