43
Heatilator • ECLIPSE-32, ECLIPSE-36 Installation Manual • 2297-984 Rev. B • 6/15
E. Air Shutter Setting
Air shutter settings should be adjusted by a quali
fi
ed
service technician at the time of installation.
The air
shutter is set at the factory for minimum vertical vent run.
Adjust air shutter for longer vertical runs.
By sliding the air shutter to the right, you will be opening
the air shutter. To adjust loosen the wing nut. Care should
be taken when adjusting the air shutter so as not to cause
the appliance to soot. If sooting occurs the air shutter will
need to be opened by sliding the air shutter to the right.
When
fi
nished, tighten the wing nut. See Figure 9.1.
NOTICE:
If sooting occurs, provide more air by opening
the air shutter.
Air Shutter Settings
Models
NG
LP
ECLIPSE-32
1/4 in.
1/2 in.
ECLIPSE-36
1/4 in.
1/2 in.
SHUTTER ADJUSTMENT
Measure from left edge of slot to center of first stud.
Figure 9.1 Air Shutter Adjustment