44
Heat & Glo • LUX36, LUX42 Installation Manual
• 2287-980 Rev. L
• 2287-980 Rev. L • 4/16
D. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances as speci
fi
ed. Framing closer than the minimums list-
ed must be constructed entirely of non-combustible materi-
als (i.e., steel studs, concrete board, etc.).
Combustible Mantel Legs or Wall Projections
Non-Combustible Mantel Legs or Wall Projections
7 IN.
MIN.
FIREPLACE
OPENING
COMBUSTIBLE OR
NON-COMBUSTIBLE WALL
14 IN. MIN.
COMBUSTIBLE
COLUMN
4 IN.MAX.
1/2 IN. BUILDING MATERIAL
FACTORY-SUPPLIED
NON-COMBUSTIBLE BOARD
Figure 10.7 Combustible Mantel Leg and Wall Projections
Figure 10.8 Non-Combustible Mantel Leg and Wall Projections
When installing a mantel, provisions must be made
in order to secure the mantel to the adjacent framing
materials. For example, lintel brackets or lag bolts may
be considered for this purpose.
FIREPLACE
OPENING
COMBUSTIBLE OR
NON-COMBUSTIBLE
WALL
14 IN. MIN.
NON-COMBUSTIBLE
COLUMN
6 IN. MAX.
1/2 IN. BUILDING MATERIAL
FACTORY-SUPPLIED
NON-COMBUSTIBLE
BOARD
SEE SECTION 10.E
FOR REQUIRED
CLEARANCES
6
12
10
18
21
FIREPLACE
OPENING
1-1/4 IN.
SEE SECTION 13.D
1/2 IN.
NON-COMBUSTIBLE
MATERIAL
LUX36
LUX42
MIN.
MAX.
Figure 10.10 Non-Combustible Mantel Allowance
Note:
All measurements in inches.
Note:
Measurement is taken from top of the opening,
NOT the top of the
fi
replace.
Non-Combustible Mantel Projections
1
9
3
6
12
9
12
15
18
21
FIREPLACE
OPENING
1/2 IN.
NON-COMBUSTIBLE
MATERIAL
LUX36
LUX42
MIN.
MAX.
Note:
All measurements in inches.
Note:
Measurement is taken from top of the opening,
NOT
the top of the
fi
replace.
Figure 10.9 Combustible Mantel Allowance
Combustible Mantel Projections