43
Heat & Glo • LUX36, LUX42 Installation Manual
•
• 2287-980 Rev. L
2287-980 Rev. L • 4/16
B. Facing Material
• Metal front faces may be covered with non-combustible
materials only.
• Facing and/or
fi
nishing materials must not interfere
with air
fl
ow through louvers, operation of louvers or
decorative fronts, or access for service.
• Facing and/or
fi
nishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
• Seal joints between the
fi
nished wall and appliance top
and sides using a 300ºF minimum sealant. Refer to
Figure 10.5.
WARNING! Risk of Fire! DO NOT
apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as speci
fi
ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of decorative fronts and
louvers.
Figure 10.5 Non-combustible Facing Diagram
0 in.
NON-COMBUSTIBLE
BOARD
A
B
COMBUSTIBLE MATERIAL
0 IN.
0 IN.
MODEL
A
B
in.
mm
in.
mm
LUX36
61
1549
57-5/8
1464
LUX42
67 1702
62-5/8
1591
Figure 10.6
C. Splatter Guard
The splatter guard is a piece of corrugated material
used to protect the appliance during the installation
process before
fi
nishing work on the whole hearth is
complete. Splatter guards may be factory installed or
accompany the decorative front of the appliance, de-
pending on the
fi
replace model. Splatter guards must
be removed before appliance is
fi
red.
WARNING! Risk of Fire!
Close the ball valve before in-
stalling the splatter guard to prevent accidental lighting.
Remove the splatter guard before lighting the appliance.
1. Fold top
fl
ap along scored lines.
2. Slide side tabs into slots by sides of glass.