24
Heat & Glo • LUX36, LUX42 Installation Manual
• 2287-980 Rev. L
• 2287-980 Rev. L • 4/16
Top Vent - Vertical Termination - (continued)
Figure 4.11
Three Elbows
Note:
Flue restrictor is permit-
ted ONLY on 30 ft. minimum
vertical runs with no elbows.
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
V
2
LUX36
V
1
H
1
Maximum
V
2
2 ft
610 mm
17 in.
432 mm
*
3 ft
914 mm
3 ft
914 mm
*
4 ft
1.2 m
4 ft
1.2 m
*
5 ft
1.5 m
9 ft
2.7 m
*
6 ft
1.8 m
12 ft
3.7 m
*
*No speci
fi
c restrictions on this value EXCEPT
V
1
+ V
2
+ H
1
+ H
2
= 50 ft (15.2 m) Max.
After V
1
= 6 ft, then H
1
Max.= V
1
x 2
LUX42
V
1
H
1
Maximum
V
2
4 ft
1.2 m
17 in
432 mm
*
5 ft
1.5 m
2 ft
610 mm
*
6 ft
1.8 m
9 ft
2.7 m
*
*No speci
fi
c restrictions on this value EXCEPT
V
1
+ V
2
+ H
1
+ H
2
= 50 ft (15.2 m) Max.
After V
1
= 6 ft, then H
1
Max.= V
1
x 2
WARNING! Risk of Fire!
• LUX36 requires a minimum of 24 inches of vertical venting before
attaching any elbow to the appliance.
• LUX42 requires a minimum of 48 inches of vertical venting before
attaching any elbow to the appliance.
DO NOT attach elbow directly to the appliance.