Close the vapor recovery (Stage ll Vapor return line) impact valve. If there is no
impact valve, be sure to have proper plugs or caps available to plug the Stage ll line
before disconnecting the Wayne-VAC
™
equipment.
Unscrew the flare nuts holding the vapor tube into the inlet of both VAC pumps, see
photo G.
Unscrew the flare nuts from the vapor port of both outlet castings and remove the
vapor tubes, see photo H.
Remove the 3/8” NPT x 3/8” flare elbow fittings from both outlet castings, see photo H.
Photo G
Photo H
Photo
I
Photo
J
Remove the 3/8” NPT x 3/8” flare straight fitting from the inlet of the VAC pump on the
“B” side and install the 3/8” pipe plug supplied in the Healy Vapor Kit, tighten
securely, see photo I.