ARB Approved IOM – Executive Orders VR-201-B and VR-202-B (Wayne Harmony WayneVac Dispenser)
Page 119
Healy Systems, Inc.
Website: http://www.healysystems.com
18 Hampshire Drive
Email: [email protected]
Hudson, New Hampshire 03051 USA
Telephone: 603.882.2472
ARB Approved Installation, Operation and Maintenance Manual (November 2006) Fax: 603.882.5189
Healy Systems, Inc. – the innovative leader of Stage II vapor recovery equipment
If diagnosing a problem where the LED is already illuminated, a steady light indicates
a low current condition, therefore expect a vane or rotor problem. If the LED is
blinking, that indicates a high current condition and would expect to find a jammed
rotor or vapor line flooded with product. See Start-up / New Installation / Warranty /
Annual Testing Form.
The electronics of the motor will make three attempts to have a successful start of the
motor. If it detects a problem, on the fourth unsuccessful start, it will short the fault
line to signal minus (DC-) and shut down the electronics.
MC100 Interface Module