ARB Approved IOM – Executive Orders VR-201-B and VR-202-B (Wayne Harmony WayneVac Dispenser)
Page 115
Healy Systems, Inc.
Website: http://www.healysystems.com
18 Hampshire Drive
Email: [email protected]
Hudson, New Hampshire 03051 USA
Telephone: 603.882.2472
ARB Approved Installation, Operation and Maintenance Manual (November 2006) Fax: 603.882.5189
Healy Systems, Inc. – the innovative leader of Stage II vapor recovery equipment
12. WIRING INSIDE THE ELECTRONICS COMPARTMENT: (See Photos Q, R, S, & T)
Photo
Q
Photo
R
In the electronics bay, locate the light assembly on the upper right side of the cabinet,
see photo Q. In photo R, notice the 3/16” hole that must be made to accept the module
mounting screw. Punch this hole approximately as shown. If drilling, be sure no
hazardous vapors are present and use a coffee cup or other suitable container to prevent
metal chips from falling inside the cabinet.
Photo S
Photo T
Leave the wires coming from the sealed nipple assembly at least six inches longer than
necessary to reach the bottom of the compartment. Cut off excess and strip all wires
1/2”.