ARB Approved IOM – Executive Orders VR-201-B and VR-202-B (Wayne Harmony WayneVac Dispenser)
Page 116
Healy Systems, Inc.
Website: http://www.healysystems.com
18 Hampshire Drive
Email: [email protected]
Hudson, New Hampshire 03051 USA
Telephone: 603.882.2472
ARB Approved Installation, Operation and Maintenance Manual (November 2006) Fax: 603.882.5189
Healy Systems, Inc. – the innovative leader of Stage II vapor recovery equipment
Connect the wires from the sealed nipple to the interface module as follows:
Black wire to ‘motor ‘ on module
White wire to ‘neutral’ on module
Red wire (either) to ‘output 1’ on module
Red wire (other) to ‘output 2’ on module
Orange wire to ‘fault common’ on module
Purple wire to ‘fault input’ on module
Green wire needs a #8 ring tong lug installed and connected to any chassis ground
(frame)
Some sealed nipples may have some extra wires, cap these and bundle them
neatly out of the way.
The black and white twisted pair of wires with a connector should be connected to an
available AC outlet on the dispenser Relay Board #887225.
The male/female multiconductor cable that is wired to the interface module is routed up
to the computer board # 173976, see photo T. Disconnect the valves cable that’s in the
J3 connector and install in the female side of the double connector on the harness. The
entire assembly is then installed back into J3 on the Computer board. WIRING IS
COMPLETE.
Mount the interface module as shown in Photo S using the 8-32 x 5/8” screw, washer and
nut supplied in the electrical kit.
Install the following labels supplied:
•
NOTICE label for current increase (1405), install on the frame rail near the
existing power consumption label.
•
Large NOTICE label (1406) relating to the vapor recovery upgrade and how to
reset the electronic module should be installed near the module, where it will be
readily visible to a service technician on the junction box cover.
•
UL, retrofit kit identification number (1410), install on the electronic module.
13. CONNECTING HEALY SYSTEMS DISPENSING EQUIPMENT
Completing the connection of Healy Systems dispensing equipment requires the
installation of Healy Systems Phase II dispenser adaptors, hoses and nozzles
(Hanging Hardware).
If applicable, remove existing non-Healy hanging hardware (from the dispenser
product outlet adaptor to and including the nozzles).