ARB Approved IOM – Executive Orders VR-201-B and VR-202-B (Wayne Harmony WayneVac Dispenser)
Page 114
Healy Systems, Inc.
Website: http://www.healysystems.com
18 Hampshire Drive
Email: [email protected]
Hudson, New Hampshire 03051 USA
Telephone: 603.882.2472
ARB Approved Installation, Operation and Maintenance Manual (November 2006) Fax: 603.882.5189
Healy Systems, Inc. – the innovative leader of Stage II vapor recovery equipment
Photo
O
Photo
P
Get the 1346 sealed nipple assembly and carefully remove the first nut and washer over
the wires. Thread these wires from inside the electronics compartment, up through the
hole inside the ”J” box, (bottom right) where the Wayne VAC
™
potted nipple was
removed. Carefully replace the washer and nut over the wires and secure the unit into
the box.
At the VP1000, get and install the 1/2” male x 3/4” female adaptor over the wires coming
from the motor. Do not use pipe dope on these fittings and be sure there is at least five
full threads of engagement of the fittings in their respective couplings.
Thread the pump wires through the elbow that was removed from the Wayne VAC
™
motor electronics housing and screw the threaded end with the “O” ring into the 1/2”
male x 3/4” female adaptor installed in the above step. Tighten so that the elbow faces
away from the “J” box, see photo P.
Get the electrical tube that was left hanging during the Wayne VAC
™
removal, and route
up to the VP1000 VAC pump as shown in photo P.
Run the electronic wires from the VP1000 through the electrical tube and into the “J” box
as shown. Reconnect the electrical tube to the elbow on the VAC pump.
In the “J” box, leave about 6” of wire on both the wires coming from the motor and from
the sealed nipple, cut off excess wire and strip approximately 1/2” of insulation from all
wires.
Use wire nuts to join the wires, color for color, together. There may be some extra wires
in some sealed nipples, cap these off and dress aside.
Keep wires clear of pinch points and from interference, make sure no wires overhang the
door openings.
Replace the cover on the junction box.