Safety instructions
MX809B
A3757-2.2
HBM: public
11
Outside the rated measurement categories
In circuits not directly connected to the supply network,
the working voltage, the level of possible transients and
the energy capacity (line impedance, overcurrent limiting
devices) must be determined before choosing suitable
measuring equipment, as the empirical values of the
measurement categories are not available to fall back on.
The values then have to be compared with the ratings of
the measuring equipment.
CAT II
Measurement category II is applicable to test and mea
suring circuits that are directly connected to the user con
nections (sockets) of the low-voltage grid installation. It is
expected that this part of the installation will have at least
three levels with overload protection elements between
the transformer and the measuring circuit connection
point.
CAT III
Measurement category CAT III is applicable to test and
measuring circuits that are connected to the distribution
circuit of the building low-voltage grid installation. It is
expected that this part of the installation will have at least
two levels with overload protection elements between the
transformer and the measuring circuit connection point.
Summary of Contents for Quantum X MX403B
Page 7: ...MX403B A3757 2 2 HBM public 5...
Page 38: ...36 A3757 2 2 HBM public MX403B...
Page 76: ...38 A3757 2 2 HBM public MX403B...
Page 283: ...Caract ristiques techniques MX809B A3757 2 2 HBM public 57...
Page 285: ...Operating Manual Bedienungsanleitung English Deutsch ITC U1001...
Page 306: ...Specifications 20 A4749 1 0 HBM public ITC U1001...
Page 327: ...Technische Daten ITC U1001 A4749 1 0 HBM public 21...
Page 350: ...Caract ristiques techniques 22 A4749 1 0 HBM public ITC U1001...
Page 351: ...Caract ristiques techniques ITC U1001 A4749 1 0 HBM public 23...
Page 374: ...Specifications 20 A4749 1 0 HBM public ITC K1000...
Page 415: ...Caract ristiques techniques ITC K1000 A4749 1 0 HBM public 21...