Test signals and signal generators
PMX
A4354-2.2
HBM: public
265
14
Test signals and signal generators
Test signals
Different types of signals can be generated and transmit
ted with the PMX. This can be a test signal during the
starting-up phase, to simulate measured values and thus
already test the functioning of the components. During
activation of a test signal, this is displayed in the PMX
browser and also transmitted on the fieldbus as a status.
Signal generators
The PMX has internal signal generators that can be set
up using the calculated channel "Signal generators". The
following functions are available in the function paramet
ers:
sine, rectangle, white noise, counter, constant and
triangle
Other parameters include:
frequency, amplitude and offset
The signal generator can also be activated with an on-
switch, with repetitions being defined by specifying the
periods.
As well as conventional waveforms, the PMX also has
the option to define a separate function by specifying up
to 21 points. These points are interconnected along a
line. The test profile can be controlled by a ramp (timer).
First the ramp for controlling the timing of the signal is
generated.
To do this, create a new calculated channel "Timer" un
der the "Technology" category. The period and the ramp
interval can be specified in its function parameters, as
well as switching between continuous and single shot
mode.
Summary of Contents for PX401
Page 1: ...Operating Manual English PMX...
Page 104: ...Electrical connections PMX 104 A4354 2 2 HBM public PMX...
Page 141: ...Startup PMX A4354 2 2 HBM public 141 Network settings...
Page 239: ...Internal calculation channels PMX A4354 2 2 HBM public 239...
Page 241: ...Internal calculation channels PMX A4354 2 2 HBM public 241...
Page 246: ...Internal calculation channels 246 A4354 2 2 HBM public PMX...
Page 264: ...Internal calculation channels 264 A4354 2 2 HBM public PMX...
Page 272: ...Parameter sets measurement programs 272 A4354 2 2 HBM public PMX...
Page 295: ...Communication with a control system PMX A4354 2 2 HBM public 295...
Page 297: ...Communication with a control system PMX A4354 2 2 HBM public 297...
Page 300: ...Communication with a control system 300 A4354 2 2 HBM public PMX...
Page 376: ...CODESYS V3 Soft PLC WGX001 only 376 A4354 2 2 HBM public PMX...
Page 378: ...CODESYS V3 Soft PLC WGX001 only 378 A4354 2 2 HBM public PMX...
Page 381: ...CODESYS V3 Soft PLC WGX001 only PMX A4354 2 2 HBM public 381...
Page 392: ...CODESYS V3 Soft PLC WGX001 only 392 A4354 2 2 HBM public PMX Dialog Updating the PMX device...
Page 489: ...Object directory PMX A4354 2 2 HBM public 489...
Page 523: ...Diagnosis and maintenance PMX A4354 2 2 HBM public 523 Network settings...