Internal calculation channels
PMX
A4354-2.2
HBM: public
247
Tips
S
Violation of the acceptance band (as opposed to com
pliance) can be indicated by inverting the logic, for
example with the limit switches.
S
I
nstead of checking the force at points on the dis
placement axis, of course it is also possible to check
displacement at certain points
S
Additional directiondependent check points can also
be set up with the appropriate number of Hold blocks.
S
P
arameter sets can be used to switch the values of
the measurement points and/or acceptance bands to
other values. A copy of the subparameter set Acquisi
tion in which the numeric values are changed has
been created for this purpose. Subparameter sets are
then assigned to different parameter sets, which are
switched for example via fieldbus or digital inputs.
Instead of individual numeric values, the structure of
calculated channels can also be switched. The limit
switches are switched by the subparameter set Limit
Switches.
Summary of Contents for PX401
Page 1: ...Operating Manual English PMX...
Page 104: ...Electrical connections PMX 104 A4354 2 2 HBM public PMX...
Page 141: ...Startup PMX A4354 2 2 HBM public 141 Network settings...
Page 239: ...Internal calculation channels PMX A4354 2 2 HBM public 239...
Page 241: ...Internal calculation channels PMX A4354 2 2 HBM public 241...
Page 246: ...Internal calculation channels 246 A4354 2 2 HBM public PMX...
Page 264: ...Internal calculation channels 264 A4354 2 2 HBM public PMX...
Page 272: ...Parameter sets measurement programs 272 A4354 2 2 HBM public PMX...
Page 295: ...Communication with a control system PMX A4354 2 2 HBM public 295...
Page 297: ...Communication with a control system PMX A4354 2 2 HBM public 297...
Page 300: ...Communication with a control system 300 A4354 2 2 HBM public PMX...
Page 376: ...CODESYS V3 Soft PLC WGX001 only 376 A4354 2 2 HBM public PMX...
Page 378: ...CODESYS V3 Soft PLC WGX001 only 378 A4354 2 2 HBM public PMX...
Page 381: ...CODESYS V3 Soft PLC WGX001 only PMX A4354 2 2 HBM public 381...
Page 392: ...CODESYS V3 Soft PLC WGX001 only 392 A4354 2 2 HBM public PMX Dialog Updating the PMX device...
Page 489: ...Object directory PMX A4354 2 2 HBM public 489...
Page 523: ...Diagnosis and maintenance PMX A4354 2 2 HBM public 523 Network settings...