254
4000511390
E03.16
USA / GB
HT21RT O - HT21RT O SW - HT61RT O - HT21RT PRO - HT21RT PRO SW - HT61RT PRO -
HT23RTJ O - HT23RTJ O SW - HT67RTJ O - HT23RTJ PRO - HT23RTJ PRO SW - HT67RTJ PRO
E
Trouble shooting and diagram
Telescope Joystick
Chk SM122Y
F05.01 (D)
Drive joystick failure : out of range [0.2..4.8] V or out of neutral incoherence
1 --> SM122Y : Analogue value out of range
2 --> SM122Y : Analogue value and SM122RrON or SM122FtON digital values are
incoherent
SM122Y
:
• Check 5V supply
• Check connection to ground
• Check joystick
Telescope Joystick
Chk SM121Y
F05.03 (D)
Boom telescoping joystick failure : Out of range [0.2..4.8] V
1 --> SM121Y : Analogue value out of range
2 --> SM121Y : Analogue value and SM121YON digital value are incoherent
SM121Y
:
• Check 5V supply
• Check connection to ground
• Check joystick
Boom Joystick
Chk SM120Y
F05.04 (D)
Boom lifting joystick failure
1 --> SM120Y : Analogue value out of range
2 --> SM120Y : Analogue value and SM120XYON digital value are incoherent
SM120Y
:
• Check 5V supply
• Check connection to ground
• Check joystick
Turret Joystick
Chk SM10X
F05.04 (D)
Turret rotation joystick failure
1 --> SM120X : Analogue value out of range
2 --> SM120X : Analogue value and SM120XYON digital value are incoherent
SM120X
:
• Check 5V supply
• Check connection to ground
• Check joystick
Joystick Neutral
Chk SM122Y
F05.11 (D)
No detection of joystick's neutral position at machine start up
SM122Y
:
• Check SM122FtON / SM122RrON
• Check 5V supply
• Check joystick
Joystick Neutral 2
Chk SM122Y
F05.12 (D)
No detection of joystick's neutral position at machine start up
SM121Y
:
• Check SM121YON
• Check 5V supply
• Check joystick
Joystick Neutral 3
Chk SM120X/Y
F05.13 (D)
No detection of joystick's neutral position at machine start up
SM121Y
:
• Check SM120XYON
• Check 5V supply
• Check joystick
F06 : Overload
No Loading Cal
Calibrate
F06.01(D)
No overload calibration, do/redo overload calibration with country option CE or AS, or
country option ANSI and Load Measurement option ACTIVE
VAR[LoadGaugesNotCalibrated]=1
Do/Redo calibration
Failure
Code
Description
Summary of Contents for HT21RT O
Page 86: ...86 4000511390 E03 16 USA GB General data Breaking test procedure MS0004 Notes...
Page 132: ...132 4000511390 E03 16 USA GB Chassis and turntable KUBOTA diesel engine MS0029 Notes...
Page 142: ...142 4000511390 E03 16 USA GB Chassis and turntable Overload system MS0017 Notes...
Page 188: ...188 4000511390 E03 16 USA GB Upper boom Boom adjustment procedure MS0015 Notes...
Page 192: ...192 4000511390 E03 16 USA GB Upper boom Boom angle sensor adjustment MS0018 Notes...
Page 222: ...222 4000511390 E03 16 USA GB Hydraulics Hydraulic oil Level Replacement MS0019 Notes...
Page 231: ...231 4000511390 E03 16 USA GB Hydraulics Hydraulic ways MS0023 F o l i o 2 2...
Page 233: ...233 4000511390 E03 16 USA GB Hydraulics Hydraulic ways MS0023 F o l i o 2 2...
Page 235: ...235 4000511390 E03 16 USA GB Hydraulics Hydraulic ways MS0023 F o l i o 2 2...
Page 237: ...237 4000511390 E03 16 USA GB Hydraulics Hydraulic ways MS0023 F o l i o 2 2...
Page 239: ...239 4000511390 E03 16 USA GB Hydraulics Hydraulic ways MS0023 7 Jib...
Page 240: ...240 4000511390 E03 16 USA GB Hydraulics Hydraulic ways MS0023 Notes...
Page 242: ...242 4000511390 E03 16 USA GB Electric Electrical wiring MS0025 Notes...