250
4000511390
E03.16
USA / GB
HT21RT O - HT21RT O SW - HT61RT O - HT21RT PRO - HT21RT PRO SW - HT61RT PRO -
HT23RTJ O - HT23RTJ O SW - HT67RTJ O - HT23RTJ PRO - HT23RTJ PRO SW - HT67RTJ PRO
E
Trouble shooting and diagram
N.B.-:- VAR[A
CTIVE
F
AILURE
] = 1
IF
ONE
OR
MORE
OF
THE
FOLLOWING
FAILURES
ARE
IN
ACTIVE
STATE
Failure
Code
Description
F02 : Contactor
Emergency Pump
Chk KM120
F02.02 (D)
Safety pump relay failure while safety pump on (open circuit or short circuit)
--> KM120
• Check relay
• Check connection to ground
• Check connection to U100 ECU
• Check connection on PCB
Power Contactor
Chk KMP
F02.04 (D)
Incoherence between the emergency stop status and the presence of voltage on power
line
--> EMSTOP = 0 & (VC>5V / VD>5V)
• Check emergency stop
• Check KMP relay
• Check fuse
• Check wiring
• Check connection on PCB
Heating Relay
Chk KM160
F02.05 (D)
Prehating relay failure (open circuit or short circuit)
--> KM160
• Check relay
• Check connection to ground
• Check connection to U100 ECU
• Check connection on PCB
F03 : Relay
Horn relay
Chk KA9
F03.06 (D)
Horn relay failure (Open circuit or short circuit)
--> KA9
• Check relay
• Check connection to ground
• Check connection to U100 ECU
• Check connection on PCB
Start Relay
Chk KA2
F03.08 (D)
Start relay failure (Open circuit or short circuit)
--> KA2
• Check relay
• Check connection to ground
• Check connection to U100 ECU
• Check connection on PCB
Supply / KeySwitch
Rel
Chk KA1
F03.09 (D)
Engine supply relay failure (Open circuit or short circuit)
--> KA1
• Check relay
• Check connection to ground
• Check connection to U100 ECU
• Check connection on PCB
Accelerator Relay
Chk KA45
F03.11 (D)
Accelerator pull relay / accelerator hold output failure (Open circuit or short circuit)
1 --> KA5
2 --> AccHold
• Check relay
• Check connection to ground
• Check connection to U100 ECU
• Check connection on PCB
Generator relay
Chk KA5
F03.10 (D)
Generator relay failure while generator on (Open circuit or short circuit)
1 --> KA5
2 --> AccHold
• Check relay
• Check connection to ground
• Check connection to U100 ECU
• Check connection on PCB
F04 : Electrovalves
Summary of Contents for HT21RT O
Page 86: ...86 4000511390 E03 16 USA GB General data Breaking test procedure MS0004 Notes...
Page 132: ...132 4000511390 E03 16 USA GB Chassis and turntable KUBOTA diesel engine MS0029 Notes...
Page 142: ...142 4000511390 E03 16 USA GB Chassis and turntable Overload system MS0017 Notes...
Page 188: ...188 4000511390 E03 16 USA GB Upper boom Boom adjustment procedure MS0015 Notes...
Page 192: ...192 4000511390 E03 16 USA GB Upper boom Boom angle sensor adjustment MS0018 Notes...
Page 222: ...222 4000511390 E03 16 USA GB Hydraulics Hydraulic oil Level Replacement MS0019 Notes...
Page 231: ...231 4000511390 E03 16 USA GB Hydraulics Hydraulic ways MS0023 F o l i o 2 2...
Page 233: ...233 4000511390 E03 16 USA GB Hydraulics Hydraulic ways MS0023 F o l i o 2 2...
Page 235: ...235 4000511390 E03 16 USA GB Hydraulics Hydraulic ways MS0023 F o l i o 2 2...
Page 237: ...237 4000511390 E03 16 USA GB Hydraulics Hydraulic ways MS0023 F o l i o 2 2...
Page 239: ...239 4000511390 E03 16 USA GB Hydraulics Hydraulic ways MS0023 7 Jib...
Page 240: ...240 4000511390 E03 16 USA GB Hydraulics Hydraulic ways MS0023 Notes...
Page 242: ...242 4000511390 E03 16 USA GB Electric Electrical wiring MS0025 Notes...