![Harvia HWS1500EU Instructions For Installation And Use Manual Download Page 30](http://html1.mh-extra.com/html/harvia/hws1500eu/hws1500eu_instructions-for-installation-and-use-manual_2104095030.webp)
EN
DE
30
Drain hose
To the drain
To the steam generator
•
Remove the plastic film around the pre-filter, and install it in the notch on the bottom of the pre-filter
housing.
•
Rotate the pre-filter housing and its cover together.
•
Check the direction of water flow from the arrows on the pre-filter housing cover. The flow direction
should be towards the water softener. Install the wall bracket with screws to the pre-filter taking the
flow direction into account.
•
Attach the pre-filter assembly to the wall / rack.
•
Attach 1 m long water hose between the pre-filter and the “Hard water” connector on the back of
the water softener. Also check the arrows on the pre-filter and water softener for correct water flow
direction. Use the ¾ ” double nipple at the end of the pre-filter as a mounting aid.
•
Attach 1.5 m long hose between the “Soft water” connector on the back of the water softener and
steam generator. Check the arrows from the water softener for correct water flow direction.
•
Open front cover of the water softener, then open two fixing screws behind back cover and carefully
lift back cover without damaging the internal electrical wiring.
•
Attach the white drain hose to the drain connector under back cover with a clamp.
•
Connect the adapters' connector to the displays' connector inside of the back cover.
•
Close the back cover.
•
Attach a hose between inlet water and pre-filter, if needed use a ¾ ”double nipple (hose not included).
•
Add about 15 cm layer of salt tablets (salt sold separately) to the water softener tank.
•
Close the cover.
•
Carefully open the inlet water and check for leaks everywhere.
•
Connect the water softener to electrics with the transformer.
Read more detailed instructions on programming the water softener and pre-filter in this manual.
¾” Reinforced hose
1 m
¾” Reinforced hose
1,5 m
¾ ” double nipple,
2 pcs
Pre-filter housing
Wall bracket
Transformer
EU/UK/US
Pre-filter
Pre-filter housing cover
Inlet water
Water softener
Summary of Contents for HWS1500EU
Page 11: ...FI SV 11 12 6 7 8 9 5 1 2 3 4 15 14 10 5 8 7 6 11 3 5 1 2 4 6 13...
Page 35: ...EN DE 35 12 6 7 8 9 5 1 2 3 4 15 14 10 5 8 7 6 11 3 5 1 2 4 6 13...
Page 59: ...ES IT 59 12 6 7 8 9 5 1 2 3 4 15 14 10 5 8 7 6 11 3 5 1 2 4 6 13...
Page 83: ...FR NL 83 12 6 7 8 9 5 1 2 3 4 15 14 10 5 8 7 6 11 3 5 1 2 4 6 13...