3 Operation
METER PANEL QUICK GUIDE
Each meter panel has a Clock, three Stereo Bargraph Meters, and an Event Timer.
CLOCK
The clock expresses time in Hours:Minutes:Seconds in either 12- or 24-hour display format. See page 2-5 for
information on setting the clock and for the clock board’s DIP switch functions.
EVENT TIMER
The event timer displays time in Minutes:Seconds:tenths of seconds. See page 2-6 for information on setting
the timer board’s DIP switches and page 3-11 for the event timer control functions.
BARGRAPH METERS
Three horizontal stereo bargraph meters display Program 1, Program 2, and either Cue or a source selected on
the Meter Switcher mdoule. The first two meters, from the left, provide separate level monitoring for the Program
1 and Program 2 buses. The third meter, Meter Switcher, shows the cue bus level (when Cue is active), or a
selected source (an external input, the Send bus, the Telco Record Base Mix, Program 3 or Program 4) as set by
the Source Selector buttons in the Aux Meter section of the Meter Switcher module (see page 3-11).
Each bar segment, from 0 down to -30, represents a 1 dB level change between bars. From -30 to -57, each bar
represents a 3 dB difference in level.
The bars are green from -57 up to -20. The -20 level is equivalent to a 0 VU setting on a mechanical meter. With
a properly set up console this results in a +4 dBu analog output (analog outputs can be level trimmed, however).
From -20 up to -3 the LEDs are yellow. Levels should normally peak in this area.
The 0, -1, and -2 bars are red to indicate the signal is dangerously close to clipping. To prevent digital distortion
on the outputs, the red bars should rarely, if ever, light up—especially the 0 bar since this indicates the signal is
at, or beyond, Full Scale Digital (the digital clipping point).
Main Meters
(Program 1 and 2 Buses)
Clock
Event Timer
Meter Switcher
(Cue or Meter Switcher
selected source)
Legacy Meter Panel
Legacy
Bargraph Meter
Left Channel Level
Right Channel Level
Separate Blue Peak
Indicators for the
Left and Right
Channels
dB below FSD*
* FSD = Full Scale Digital, or 0 on the meters—the maximum console output level
Summary of Contents for Legacy 99-1300-0
Page 2: ...Revision B 1 03 H A R R I S C O R P O R A T I O N ii...
Page 6: ...Revision B 1 03 H A R R I S C O R P O R A T I O N vi...
Page 43: ...2 Installation Revision B 1 03 H A R R I S C O R P O R A T I O N 2 31 BLANK PAGE...
Page 49: ...2 Installation Revision B 1 03 H A R R I S C O R P O R A T I O N 2 37 BLANK PAGE...
Page 68: ...Revision B 1 03 H A R R I S C O R P O R A T I O N 2 56 2 Installation BLANK PAGE...
Page 94: ...Revision B 1 03 H A R R I S C O R P O R A T I O N 5 4 5 Accessories BLANK PAGE...
Page 98: ...Revision B 1 03 H A R R I S C O R P O R A T I O N INDEX 4 Index BLANK PAGE...