2-52
2 Installation
PIN # SIGNAL
FUNCTION
1
LOGIC GROUND
Module logic ground.
2
LOGIC GROUND
Module logic ground.
3
LOGIC GROUND
Module logic ground.
4
STOP COMMAND PULSE
Stop command output. N/O relay contact.
5
START COMMAND PULSE
Start command output. N/O relay contact.
6
LOGIC 5VDC
5 volt source.
7
ON INPUT (-)
Remote On switch input (active low).
8
OFF INPUT (-)
Remote Off switch input (active low).
9
COUGH INPUT (-)
Remote Cough switch input (active low).
10
LOGIC 5VDC
5 volt source.
11
LOGIC 5VDC
5 volt source.
12
LOGIC 5VDC
5 volt source.
13
COMMAND COMMON
Start/Stop Pulse, Start Sustained common. C relay contact.
14
TALLY RELAYS COMMON
Tally relays common connection. C relay contact.
15
LOGIC ACTIVE TALLY
Logic active tally output. N/O relay contact.
16
OFF TALLY
Off tally output. N/O relay contact.
17
ON TALLY
On tally output. N/O relay contact.
18
ACTIVATE INPUTS (+)
+VDC to enable external inputs On, Off, Cough, Talkback.
19
RESET (-)
Remote Audio Off input (active low).
20
TALK TO C/R INPUT (-)
Remote Talkback input (active low).
21
READY (-)
Remote Ready input (active low).
22
RESET (+)
+VDC to enable Audio Reset function (audio off control).
23
START SUSTAINED
Start sustained command output. N/O relay contact.
24
READY (+)
+VDC to enable the Ready function (Off lamp control).
Notes:
+VDC is b5 and +40 VDC.
Output relays can switch voltages up to +60 VDC
Bold
indicates connections used in this example.
UNIVERSAL INPUT MODULE LOGIC CONNECTOR SIGNAL TABLE
12
11
10
9
8
7
6
5
4
3
2
1
24
23
22
21
20
19
18
17
16
15
14
13
(wire insertion
end view)
Basic Logic Connection Example
This example shows how to set up a Universal Input module (A input) to interface with a CD
player, such as the Denon DN-951/961. For more information on logic connections and DIP
switch settings for the Universal Input module, see pages 2-18 through 2-21.
DS1 AND DS2 SWITCH SETTINGS, AS USED WITH A CD PLAYER
#
Switch Name
Setting
1
Signal Source *
ON
2
CR Mute
OFF
3
Studio Mute
OFF
4
Spare Switch
5
External Site Mute
OFF
6
Local ON Cough
OFF
7
Timer Reset
ON
8
Off Lamp Control
OFF
DS1
#
Switch Name
Setting
1
Fader Start
OFF
2
Start Pulse
OFF
3
Start/Stop Pulse
OFF
4
Bypass SRC Converter
OFF
5
Spare Switch
OFF
6
Spare Switch
OFF
7
Input Level Set A
OFF
8
Input Level Set B
OFF
DS2
Note: Set the switch to the operator’s left for ON. Set the switch to the operator’s right for OFF.
* Digital input shown
Summary of Contents for Legacy 99-1300-0
Page 2: ...Revision B 1 03 H A R R I S C O R P O R A T I O N ii...
Page 6: ...Revision B 1 03 H A R R I S C O R P O R A T I O N vi...
Page 43: ...2 Installation Revision B 1 03 H A R R I S C O R P O R A T I O N 2 31 BLANK PAGE...
Page 49: ...2 Installation Revision B 1 03 H A R R I S C O R P O R A T I O N 2 37 BLANK PAGE...
Page 68: ...Revision B 1 03 H A R R I S C O R P O R A T I O N 2 56 2 Installation BLANK PAGE...
Page 94: ...Revision B 1 03 H A R R I S C O R P O R A T I O N 5 4 5 Accessories BLANK PAGE...
Page 98: ...Revision B 1 03 H A R R I S C O R P O R A T I O N INDEX 4 Index BLANK PAGE...