5-38
888-2463-001
3/6/08
WARNING: Disconnect primary power prior to servicing.
Diamond Series™
Section 5 Maintenance and Alignments
Table 5-3 S1, Cabinet ID Switch Settings
Table 5-4 Dipswitch S6, AC Fail/External Interlock Settings
NOTE:
To use S6-6 thru S6-10 separate from a common external interlock requires
removal of JP17 on the Cabinet Controller Board.
S1 Switch
Position
Cabinet
Position
1
1
2
2
3
3
4
4
5
5
S6 Switch
Position
Function
1
AC_FAIL reporting to Control Cabinet. Set to ON For Cabinet #1 (Otherwise OFF)
2
AC_FAIL reporting to Control Cabinet. Set to ON For Cabinet #2 (Otherwise OFF)
3
AC_FAIL reporting to Control Cabinet. Set to ON For Cabinet #3 (Otherwise OFF)
4
AC_FAIL reporting to Control Cabinet. Set to ON For Cabinet #4 (Otherwise OFF)
5
AC_FAIL reporting to Control Cabinet. Set to ON For Cabinet #5 (Otherwise OFF)
6
External Interlock for Cabinet #2. Set to ON if separate external interlocks are being used for
each PA Cabinet. Set to OFF if all PA Cabinet are wired to a common external interlock.
7
External Interlock for Cabinet #3. Set to ON if separate external interlocks are being used for
each PA Cabinet. Set to OFF if all PA Cabinet are wired to a common external interlock.
8
External Interlock for Cabinet #4. Set to ON if separate external interlocks are being used for
each PA Cabinet. Set to OFF if all PA Cabinet are wired to a common external interlock.
9
External Interlock for Cabinet #5. Set to ON if separate external interlocks are being used for
each PA Cabinet. Set to OFF if all PA Cabinet are wired to a common external interlock.
10
Set to ON if the Cabinet Interlock is to be used. This interlock is separate from the external
interlocks and is not normally used. If set to ON, a closure between J8-1 and J8-4 (on top of
the PA Cabinet) is required.
NOTE: See drawing # 843-5495-538 in the schematic package for simplified diagrams of
the various transmitter interlock configurations.