Chapter 5 Video Configuration
© 2013 Harmonic Inc. Harmonic All rights reserved.
123
Ellipse 3000 Release 3.0, Rev. B
Ancillary Data Sub-Menu/Box
■
AFD Bar Data Fallback
– Use this parameter to manage the bar data value inserted in the
encoded video stream if there is no AFD VANC in the input. This parameter only displays when
the
AFD Bar Data
parameter is set to
Insert
. Options:
❑
16:9 full frame (1000)
(Default)
❑
4:3 pillarbox (1001)
❑
16:9 full frame (1010)
❑
14:9 pillarbox (1011)
❑
4:3 pillarbox, alternative 14:9 center (1101)
❑
16:9 full frame, alternative 14:9 center (1110)
❑
16:9 full frame, alternative 4:3 center (1111)
■
Time Code
– Configurable for SDI input only. Options:
❑
VITC
–
❑
Discard
– (Default)
Close Caption
– The Ellipse 3000 encoders are SMPTE 333 interface compliant for external closed
caption servers over RS-232. The Ellipse 3000 encoders are SMPTE 334-1 closed caption data
mapping compliant. CEA-608 (line 21) is not supported in MPEG-2
❑
Discard
– (Default)
❑
CEA-708 (SMPTE 334-1)
–
❑
CEA-608 (SMPTE 334-1)
–
❑
CEA-708 (SMPTE 333)
–