Chapter 3 ’Web User Graphical Interface’ — Workflow Library
240
Electra VS - Version 05.10
User Manual - Rev. A
Processing Component Specific Parameters
This section lists all processing components and details their specific
parameters. Processing components are sorted by category.
Inputs
TS over IP Input
Description
The
TS over IP input
processing component manages a MPEG-2 TS,
over UDP/IP or RTP/UDP/IP.
MPTS (multiple program) and SPTS (single program) are supported.
CBR and VBR TS are supported.
Figure 3-218. TS over IP input parameters
Parameters
For this processing component, you must set the following parameters:
IP address
: set the IP and LAN parameters. If it is a unicast address,
it must be part of a local network and must be consistent with the IP
configuration of the Electra VS.
Figure 3-219. IP parameters
225.1.4.5#4 stands for
IP = 225.1.4.5 on LAN 4
Summary of Contents for ELECTRA VS
Page 1: ...Rev A ELECTRA VS Convergent Video System Version 05 10 User Manual...
Page 2: ...Copyright 2017 Harmonic Inc All rights reserved...
Page 448: ...Chapter 4 Servicing Virtualization Delivery 448 Electra VS Version 05 10 User Manual Rev A...
Page 560: ...Appendix C Safety Instructions 560 Electra VS Version 05 10 User Manual Rev A...
Page 562: ...Appendix D Regulatory Notices 562 Electra VS Version 05 10 User Manual Rev A...
Page 572: ...Appendix E Logs List of Logs 572 Electra VS Version 05 10 User Manual Rev A...
Page 592: ...Appendix H Aspect Ratio Conversions 592 Electra VS Version 05 10 User Manual Rev A...
Page 603: ...Glossary Electra VS Version 05 10 603 User Manual Rev A...
Page 604: ...www harmonicinc com Copyright 2017 Harmonic Inc All rights reserved...