A.2 YukonDrive® technical data
Table 49.1 technical data YukonDrive® - 1021/-1031/-1041
Designation
Technical data
-1021
-1031
-1041
Output. motor side
1)
Voltage
3-phase U
Netz
Effective continuous current (l
N
)
2)
3 A
5.9 A
8 A
Peak current (A
eff
)
see table 44.1 and 44.2
Rotating field frequency
0 ... 400 Hz
Switching frequency of power stage
4. 8. 16 kHz
Input. mains side
Mains voltage
(1 x 230 V AC / 3 x 230 V AC) -20 %/+15 %
Device connected load
1)
(with line reactor)
1.3 kVA
2.6 kVA
3.5 kVA
Current
1)
(with line reactor)
5.4 A
3.3 A
10.6 A
6.5 A
14.4 A
8.8 A
Asymmetry of mains voltage
±3 % max.
Frequency
50/60 Hz ±10 %
Power loss at I
N
1)
75 W
150W
200 W
Braking chopper power electronics
Peak braking power with int. braking resistor
400 W in 550 Ω PTC)
4)
1.5 kW in 100 Ω
5))
1.7 kW in 90Ω
5)
Minimum ohmic resistance of an externally installed
braking resistor
72 Ω
72 Ω
3)
72 Ω
3)
1)
Values referred to mains voltage 230 V AC and switching frequency 8 kHz.
2)
For rated current refer to table 33!
3)
Connection of ext. braking resistor not permitted to devices with int.braking resistor!
4)
Braking resistor always integrated. Connection of an external resistor is permissible.
5)
Option
Note:
For more information on the braking chopper switch-on threshold also refer to section 3.14 as from page 31.
1 x 230 V AC
3 x 230 V AC