48
1003370 05/2016 V01
Table 48.1 Rated current and peak current, BG2 to BG4 (3 x 400/460/480 V AC)
Device
Switching
frequency
of power
stage
Ambient
tempera-
ture
Rated current
I
N
[A
eff
]
Peak current
2)
200 % (2 I
N
)
300 % (3 I
N
)
[kHz]
max. [°C]
at 400 V
at 460 V
at 480 V
[A
eff
]
for time
[s]
[A
eff
]
for time
[s]
-1022
4
45
2.0
2.0
2.0
4.0
10
6.0
0.08
8
40
2.0
2.0
1.7
4.0
6.0
1)
16
40
0.7
0.7
–
1.4
2.8
1)
-1032
4
45
5.5
4.8
4.6
7.0
10
10.5
0.08
8
40
3.5
3.5
2.6
7.0
10.5
1)
16
40
2.2
1.3
–
4.4
6.6
1)
-1042
4
45
8.5
7.4
7.0
13.0
10
19.5
0.08
8
40
6.5
6.5
6.5
13.0
19.5
1)
16
40
4.0
2.4
1.9
8.0
12.0
1)
1)
Automatic power stage switching frequency change to 4 kHz.
2)
Data referred to 3 x 400 V mains voltage
Data applies to motor cable length ≤10 m. Maximum permissible motor cable length 30 m.
YukonDrive® for 3 x 400/460/480 V