Chapter 5 – Configuration
Hardy H6800 Series Application Controllers User Guide
57
Figure 5-2. Accessing the Set-up Parameters with a 7-inch Display
If the display is not being used, access the embedded Webserver using the default IP
address
192.168.0.100
and any browser following the steps for a LAN or Direct Connection
below. Parameters can also be accessed and set via a PLC.
5.1.2 Using an Ethernet Connection
The HM6800 Application Controller has an embedded webserver that allows configuration of
parameters using a standard web browser. Connection can be made either directly to a PC
or through an Ethernet network via a router or switch.
The rear panel of the application controller has two 10/100 BASE-T Ethernet ports for linking
to any Windows personal computer. Once connected, Hardy firmware updates can be
monitored, controlled, configured, or downloaded. The browser also provides links to the
Hardy website, where additional services and support can be found.
To establish a working connection, both sides of the link require their IP addresses to be
configured.
1. Use a standard Ethernet cable with RJ-45 connectors at each end to connect the HI6800
Application Controller to a PC, router, or switch. A crossover cable is not required.
2. Find the application controller’s fixed IP address:
a. With the application controller turned on, navigate to the
Communication
menu under
Setup
.