49
ODROID C1 USER MANUAL
C1 either via a serial connection or SSH.
Prior to setting up the kit, power off the C1. Attach one end of
the USB / UART module to the C1. Attach the other (micro USB) end
of the USB / UART module to the USB cable. Attach the free end of
the cable to an available USB port of the host PC system, then power
on the C1.
Windows Host Setup
The Windows 7+ host PC system will recognize the module as a
Silicon Labs CP210x USB to UART Bridge and install the appropriate
device driver. After installation has completed, you can verify which
COM port the module is associated. Launch the Computer Manage-
ment utility of Windows 7+, highlight the Device Manager option, and
expand the Ports list. In this particular case, as shown in the below ex-
ample screenshot, it can be see that the module is installed on COM8.
USB / UART module on COM8
Launch PuTTY and select the Serial option on the left pane.
Serial line to connect to: COM8
Speed (baud): 115200
Data bits: 8
Stop bits: 1
Parity: None
Flow Control: XON/XOFF
Serial configuration in PuTTY
Chapter 4