11 - Fault finding
73
Alarm list
Alarm warnings are flashing in the bottom line of the display - 3 seconds ON, 3 seconds OFF. The flashing alarm and an
optional alarm sound will stop, when
is pressed, or when the cause of the alarm has been corrected (non-alarm
condition).
If the alarm is stopped by pressing
, the alarm will be active again when going from alarm condition to non-alarm
condition and back to alarm condition again.
Only the first incoming alarm will flash in the display. The next alarm will flash only after the first alarm is stopped by pressing
. The alarms have no order of priority.
÷
NOTE! Alarms no. 10 - 14 relate to the DynamicFluid 4 (DF4) system on the sprayer.
ID NO. TYPE
TEXT IN DISPLAY
PROBABLE CAUSE
CONTROL/REMEDY
1
Alarm
Alarm:VolumeRate
Volume rate deviation is higher than the
defined value.
Adjust settings in menu 2.5.1.
2
Alarm
Alarm:Tank cont.
Tank contents is less than the defined
value.
Adjust settings in menu 2.5.1.
3
Alarm
Alarm:PressureHi
Boom pressure is higher than the defined
value.
Adjust settings in menu 2.5.3.1.
Decrease driving speed or change to a bigger nozzle.
4
Alarm
Alarm:PressureLo
Boom pressure is lower than the defined
value.
Increase driving speed (if safe) or change to a smaller
nozzle.
Adjust settings in menu 2.5.3.2.
5
Alarm
Alarm:Rpm Hi
Speed for the TWIN blower is higher than
the defined value.
Adjust settings in menu 2.5.4.1.
6
Alarm
Alarm:Rpm Lo
Speed for the TWIN blower is lower than
the defined value.
Adjust settings in menu 2.5.4.2.
7
Alarm
Alarm:Speed Max.
The driving speed is higher than the
defined value.
Adjust settings in menu 2.5.5.1.
8
Alarm
Alarm:Speed Min.
The driving speed is lower than the
defined value.
Adjust settings in menu 2.5.5.2.
9
Alarm
Sections: OFF!
Main ON/OFF is switched ON, and one or
more spray sections are OFF.
Note that one or mores sections are switched OFF.
10
Alarm
SENSOR ALARM
Regvlv sens.miss
Feedback sensor for the regulation valve
is deviating, disconnected or missing.
Check installation of this sensor.
11
Alarm
SENSOR ALARM
Flow sens. miss
Boom flow sensor is disconnected or
missing.
Check installation of this sensor.
12
Alarm
SENSOR ALARM
Press.sens.miss
Boom pressure sensor is disconnected or
missing.
Check installation of this sensor.
13
Alarm
SENSOR ALARM
RPM sens. fail
Sensor for pump speed (rpm) is
disconnected or missing.
Check installation of this sensor.
14
Alarm
Regulation valve
Motor fail
Problem with regulation valve control.
Electric motor for regulation valve has an internal failure,
or the wiring between motor and valve is broken.
15
Alarm
SENSOR ALARM
5V supply
Short circuit of a sensor with 5 volt supply. Contact your HARDI sevice centre.
16
Alarm
SENSOR ALARM
12V supply
Short circuit of a sensor with 12V supply. Contact your HARDI sevice centre.
Summary of Contents for HC 5500 SPRAY BOX III
Page 6: ...Table of Contents 6 ...
Page 8: ...1 EC Declaration 8 ...
Page 10: ...2 Safety notes 10 ...
Page 22: ...3 Description 22 ...
Page 28: ...4 System setup 28 ...
Page 56: ...7 Menu 3 Calibration 56 ...
Page 64: ...8 Menu 4 Toolbox 64 ...
Page 68: ...10 Maintenance 68 ...
Page 74: ...11 Fault finding 74 ...
Page 80: ...13 Technical specifications 80 ...
Page 82: ...Index 82 ...
Page 84: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...