7 - Menu 3, Calibration
53
Menu 3.5 Tank gauge
General info
This menu item is only present, if the HARDI Tank Gauge is fitted. For increased accuracy, it is recommended to do the flow
calibration before proceeding. See menu [3.2.3 Tank method].
The tank content is measured from the bottom of the main tank using a fluid pressure sensor.
The accuracy is affected of the sprayer being level. Assume that if the sprayer’s hitch point height measured from the ground
is 550 mm, then the readout of tank contents changes with the height of the sprayer at the hitch point. Also when driving
on uneven or sloping ground, the readout will vary, as the fluid pressure changes above the sensor.
If the tank gauge is replaced, it must be recalibrated.
Menu 3.5.1 Adjustment
The correction factor for the specific gravity of the liquid sprayed can be
set.
÷
NOTE! Default value is 1.000.
For liquid fertilizers, the density is often higher than for water mixed with
pesticides, and the specific gravity (or density) might be 1.3 kg/litre. The
value in this case would be 1.300.
Method
1. Press
to change value.
2. Use
and
to select the digit to be changed.
3. Change digit by pressing
and
.
4. Repeat until all digits are correct. Save setting by pressing
.
TANK GAUGE
Adjustment
3.5.1
ADJUSTMENT
Spec. grav.
X.XXX
3.5.1
Summary of Contents for HC 5500 SPRAY BOX III
Page 6: ...Table of Contents 6 ...
Page 8: ...1 EC Declaration 8 ...
Page 10: ...2 Safety notes 10 ...
Page 22: ...3 Description 22 ...
Page 28: ...4 System setup 28 ...
Page 56: ...7 Menu 3 Calibration 56 ...
Page 64: ...8 Menu 4 Toolbox 64 ...
Page 68: ...10 Maintenance 68 ...
Page 74: ...11 Fault finding 74 ...
Page 80: ...13 Technical specifications 80 ...
Page 82: ...Index 82 ...
Page 84: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...