27
-
30
Hanskamp AgroTech B.V. (the Netherlands)
www.hanskamp.nl/en
MultiDos
EN
Dosing system –
Dosiersystem –
Systeme de dosage
-
Doseersysteem
Annex 5 hazard warnings an use instructions HanskampQualityTube
003
-
512
-
00* HanskampQualityTube
For (milkingmachine) dealers, resellers and users of the MultiDos.
Attention! Not intended for medical use.
Please read carefully prior to using or reselling.
The next warnings and regulations need to be followed to prevent fractures in
-
and
leaking of the hose, which can result into material and/or physical damage to humans
an/or animals.
Warning:
1.
The HanskampQualityTube is made of
‘
Thermoplastic Material
’,
and as such, the
performance is affected by temperature and pressure.
2.
Some fluids can be absorbed by tubing material or can extract substances from
the HanskampQualityTube. It is the responsibility of the end user to specify and
document tubing performance and safety requirements.
3.
Tubing performance including life in a specific application is affected by the mate-
rials that come into contact with the tubing as well as the operating environment.
It is the responsibility of the user to determine suitability of tubing formulation for
each application.
4.
The HanskampQualityTube is not intended or recommended for medical applica-
tions. The use of this product in any medical application is solely the responsibility
of the (milking machine) dealer and/or end user.
5.
To avoid catastrophic disconnecting during use, always use retaining clamps or
adhesives when affixing tubing to fittings and/or connectors.
6.
The end user should have system back up and adequate procedures in case of
tubing rupture.
7.
No tubing will last forever. This is especially true in the MultiDos where, upon ex-
tended use or improper installation, the tubing will rupture.
The following factors have been found to influence HanskampQualityTube life in the
MultiDos liquid pump:
-
Fluid being pumped/transported
-
percentage occlusion of tubing walls
-
Pump speed (i.e. roller impacts/minute) and total numer of impacts
-
Amount of system back pressure
-
Temperature of fluid being transported as well as temperature of the operating
environment
-
Frictional drag due to improper maintenance or wearing of rollers and guides
-
Twisting, kinking, or excess lengths of the HanskampQualityTube installed in the
MultiDos.
-
Wall thickness and thickness variation