16
-
30
Hanskamp AgroTech B.V. (the Netherlands)
www.hanskamp.nl/en
MultiDos
EN
Dosing system –
Dosiersystem –
Systeme de dosage
-
Doseersysteem
14.
Take the rotor to turn it on the side of the recess
(protruding side)
in the shaft of
the pump motor. With the last tightening turn, press the HanskampQualityTube
into the recess of the pump. The tube is now clamped between the rollers and the
pump casing. Turn the rotor by hand on the motor shaft (fig. 36 and 37).
Note! The tube must be placed as perfect
as possible in the curve of the pump
(fig. 37).
15.
Take the transparent cover (art.nr. 003
-
502
-
000) with the associated four long
flange head screws (art.nr. 003
-
509
-
000). Position the cover so that it is right for
the recess in the pump. Tighten the screws evenly until the lid is tight. Note: solid
fixed! (fig. 38 and 39)
16.
Connect the motor of the MultiDos to the control board of the feeding station.
First, make the control board voltage free, before connecting the motorcable.
Attention! During the connecting of the motor to the control board, light
electric shocks can exist.
Maintenance:
Check the MultiDos on faults and wearing on a daily basis. Do this by means of a test on
the output of de tubes and electric cables. Check periodical the quantity and calibrate if
necessary.
When the HanskampQualityTube is worn by intensive use (leaking), replace it
according described steps. A repair kit is available by Hanskamp. Also check the rollers
and bearings for wear. Also these parts are available as a repair kit by Hanskamp.
We recommend to disconnect the rotor when the system is temporarily decommis-
sioned. Replace the HanskampQualityTube every year, or after pumping 1000L of fluid.
Calibration:
For calibration: operate the motor manually till the liquid emerges from the nozzle.
Attention! During the first rotations you will not see anything
happen, this is because the rotor gets fastened to the axel of
the motor.
The MultiDos is calibrated by allowing the feeding computer to emit a
pulse ten times. Then you measure the amount of dispended liquid, divide
this by 10 and enter this value into the feeding computer. Repeat this pro-
cedure every month and also after changing the liquid. This is one of the
possibilities for calibration. When the manual of your feeding computer
describes another method of calibrating, you need to apply that way of
calibrating the MultiDos.
Installation instruction Process Computer
Nedap: (001
-
669
-
000 motor SolidState5)
-
Dosage volume:
30 (equals 3cc dosage volume of MultiDos)
-
Interval/dispensing speed
5sec/0,6kg/min.
Configure the minimum and maximum feeding speed per interval according to the same
ratio as feedstuffs 1 and 2. Thereto don
’
t enter the same numbers, but enter as a ratio of
concentrates/ liquid additive.
Configuring liquid additive can be done in the same way as configuring chop. But the
dosage weight is a tenth (1/10) part of the programmed weight.
Example:
Programmed feed 3: 0,10 is the same as 10cc liquid additive
Programmed feed 3: 1,00 is the same as 100cc liquid additive
36
37
38
39