Note! The tube must be placed as perfect
as possible in the curve of the
pump (fig. 21)
21.
Take the transparent cover (art.nr. 003
-
502
-
000) with the associated four long
flange head screws (art.nr. 003
-
509
-
000). Position the cover so that it is right for
the recess in the pump. Tighten the screws evenly until the lid is tight. Note: solid
fixed! (fig. 22)
22.
Connect the motor of the MultiDos to the control board of the feeding station.
First, make the control board voltage free, before connecting the motorcable
Attention! When connecting the motor to the control board, it is possible
that light electric shocks can occur.
23.
Always mount the cover, so that dirt and dust can
’
t fall into the container.
24.
With one pump unit: mount a stainless steel blind plate on the other side of the
container. Fasten the blind plate with the including socket screws (fig.24) (art.nr.
003
-
545
-
000)
Maintenance:
Check the MultiDos on faults and wearing on a daily basis. Do this by means of a test
on the output of de tubes and electric cables. Check periodical the quantity and cali-
brate if necessary.
When the HanskampQualityTube is worn by intensive use (leaking),
replace it according described steps. A repair kit is available by Hanskamp.
Also check the rollers and bearings for wear. Also these parts are available
as a repair kit by Hanskamp.
Attention! Replace the HanskampQualityTube every year, or after
pumping 1000L of fluid.
Calibration:
For calibration: operate the motor manually till the liquid emerges from the
nozzle.
Attention! During the first rotations you will not see anything hap-
pen, this is because the rotor gets fastened to the axel of the
motor.
The MultiDos is calibrated by allowing the feeding computer to emit a pulse ten
times. Then you measure the amount of dispended liquid, divide this by 10 and
enter this value into the feeding computer.
Repeat this procedure every month and also
after changing the liquid. This is one of the
possibilities for calibration. When the manual