9
-
30
Hanskamp AgroTech B.V. (the Netherlands)
www.hanskamp.nl/en
MultiDos
EN
Dosing system –
Dosiersystem –
Systeme de dosage
-
Doseersysteem
9.
Take the already present delivery hose and pull this through the rear wall of the
pump housing to the front.
10.
Attach the feed
-
through coupling (art. no. 003
-
572
-
000) in the container and on
the delivery hose as indicated in diag.7.
11.
Afterwards mount the suction hose (art.no. 003
-
575
-
000) on the feed
-
through
coupling as indicated in diagram 8.
12.
Take the pump, remove the four long screws (art. no. 003
-
509
-
000) and take the
transparent cover of the pump housing (art. no. 003
-
502
-
000) (diag. 9)
13.
Push the end of the electrical cable from the motor into the hole of the container
which also contains the pressure hose. (fig. 8)
14.
Move the pump into the container, make sure the cable and the pressure hose
are not pinched.
15.
Install the pump with the corresponding screws (art.nr. 003
-
510
-
000) evenly by
hand.
Take care! HanskampQualityTube is not suitable for acids.
A hose set suitable for acids is available from Hanskamp.
7
10
11
8
9